ot-fit-75.220-240.550-d-lt2-l.jpg

ot-fit-75.220-240.550-d-lt2-l.jpg

ot-fit-75.220-240.550-d-lt2-l-op-win.jpg

CONSTANT CURRENT POWER SUPPLY for LED OT FIT 75/220-240/550DLT2L 125-550mA 54-216V

OT FIT 75 / 220-240 / 550 D LT2 L
The value of the output current is regulated by mounting a resistor with the appropriate resistance (according to the datasheet).

Electrical data
Rated input voltage220 ... 240 V
Line frequency 0/50/60 Hz Hz
Input voltage, alternating current198 ... 264 V
Input voltage, direct current176 ... 276 V
Current setLEDset
Total harmonic distortion <5%
Power factor λ> 0.98
Efficiency EUZ93%
Power losses 0.74 W
Protective conductor <0.5 mA
Initial inrush current41 A
Max. SE with fuse 10 A16
Maximum number of SEs for circuit breaker 16 A26
Resistance to nap. Impact (L / N-earth) 2 kV
Impact resistance (L-N) 1 kV
Rated output voltage54 ... 216 V
U-OUT (operating voltage) <250 V
Rated output current 125 ... 550 mA
Output current tolerance ± 3%
A frequency of the output current (100 Hz) <1%
Rated power6,8 ... 75 W
Galvanic isolation Non-isolated
Isolation between the primary and secondary circuit -

Dimensions and weight
Length 280 mm
Width30.0 mm
Height21.0 mm
A distance of assembly holes, length 270 mm
Product weight 203.00 g
Wire cross-section, input side 0.5 ... 1.5 mm²
Wire cross-section, outlet side 0.5 ... 1.5 mm²
Cable length, input side8,5 ... 9.5 mm
Cable length, output side8,5 ... 9.5 mm

Temperatures and working conditions
Ambient temperature range -25 ... + 50 ° C
Max. Temp. At the measuring point tc75 ° C
Max. Housing temperature110 ° C
Relative humidity5 ... 85%

Durability
Durability SE50000 h

Additional product data
Housing (with admixtures) No.
Dimming options No
Overheat protection. Automatically reversible
Overload protection. Automatically reversible
Short circuit protection. Yes
Without protection przeciwprzeciążeniowegoTak
Max. Length of wires for the lamp/module LED2.0 m
Suitable for luminaires with protection class I
Suitable for emergency lighting. Yes
Connection type, on the output side

Certificates and Standards
Marks of the research station
Marks of the research station EL
The signs of the VDE-EMC research station
The characters of the research station ENEC 10
Characters of the CCC research station
Characters of RCM research stations
NormyWg. EN 61347-1 / Wg. EN 61347-2-13 / Wg. EN 55015 / Wg. EN 61547 / Wg. EN 61000-3-2 / Wg. EN 62384 / Acc. to EN 62386
Safety class I
Protection typeIP20

 

Datasheet for download OT FIT 75/220-240/550 D LT2 L

Zapytaj o ofertę: CONSTANT CURRENT POWER SUPPLY for LED OT FIT 75/220-240/550DLT2L 125-550mA 54-216V